SubtitleEdit/build.bat
2019-05-02 07:19:04 +02:00

178 lines
5.9 KiB
Batchfile

@ECHO OFF
SETLOCAL
CD /D %~dp0
rem Check for the help switches
IF /I "%~1" == "help" GOTO SHOWHELP
IF /I "%~1" == "/help" GOTO SHOWHELP
IF /I "%~1" == "-help" GOTO SHOWHELP
IF /I "%~1" == "--help" GOTO SHOWHELP
IF /I "%~1" == "/?" GOTO SHOWHELP
for /f "usebackq tokens=1* delims=: " %%i in (`vswhere -latest -requires Microsoft.Component.MSBuild`) do (
if /i "%%i"=="installationPath" set InstallDir=%%j
)
IF "%~1" == "" (
SET "BUILDTYPE=Build"
) ELSE (
IF /I "%~1" == "Build" SET "BUILDTYPE=Build" & GOTO START
IF /I "%~1" == "/Build" SET "BUILDTYPE=Build" & GOTO START
IF /I "%~1" == "-Build" SET "BUILDTYPE=Build" & GOTO START
IF /I "%~1" == "--Build" SET "BUILDTYPE=Build" & GOTO START
IF /I "%~1" == "Clean" SET "BUILDTYPE=Clean" & GOTO START
IF /I "%~1" == "/Clean" SET "BUILDTYPE=Clean" & GOTO START
IF /I "%~1" == "-Clean" SET "BUILDTYPE=Clean" & GOTO START
IF /I "%~1" == "--Clean" SET "BUILDTYPE=Clean" & GOTO START
IF /I "%~1" == "Rebuild" SET "BUILDTYPE=Rebuild" & GOTO START
IF /I "%~1" == "/Rebuild" SET "BUILDTYPE=Rebuild" & GOTO START
IF /I "%~1" == "-Rebuild" SET "BUILDTYPE=Rebuild" & GOTO START
IF /I "%~1" == "--Rebuild" SET "BUILDTYPE=Rebuild" & GOTO START
ECHO. & ECHO Unsupported commandline switch!
GOTO EndWithError
)
:START
PUSHD "src"
TITLE %BUILDTYPE%ing SubtitleEdit - Release^|Any CPU...
ECHO %InstallDir%
IF exist "%InstallDir%\MSBuild\15.0\Bin\MSBuild.exe" (
"%InstallDir%\MSBuild\15.0\Bin\MSBuild.exe" SubtitleEdit.sln /t:%BUILDTYPE% /p:Configuration=Release /p:Platform="Any CPU"^
/maxcpucount /consoleloggerparameters:DisableMPLogging;Summary;Verbosity=minimal
IF %ERRORLEVEL% NEQ 0 GOTO EndWithError
) ELSE (
IF exist "%InstallDir%\MSBuild\Current\Bin\MSBuild.exe" (
"%InstallDir%\MSBuild\Current\Bin\MSBuild.exe" SubtitleEdit.sln /t:%BUILDTYPE% /p:Configuration=Release /p:Platform="Any CPU"^
/maxcpucount /consoleloggerparameters:DisableMPLogging;Summary;Verbosity=minimal
IF %ERRORLEVEL% NEQ 0 GOTO EndWithError
) else (
ECHO Cannot find Visual Studio 2017
GOTO EndWithError
)
)
IF /I "%BUILDTYPE%" == "Clean" GOTO END
ECHO.
ECHO ILRepack...
"packages\ILRepack.2.0.16\tools\ILRepack.exe" /parallel /internalize /targetplatform:v4 /out:"bin\Release\SubtitleEdit.exe" "bin\Release\SubtitleEdit.exe" "bin\Release\libse.dll" "bin\Release\zlib.net.dll" "bin\Release\NHunspell.dll" "DLLs\Interop.QuartzTypeLib.dll"
ECHO.
ECHO.
POPD
CALL :SubDetectSevenzipPath
IF DEFINED SEVENZIP IF EXIST "%SEVENZIP%" (
CALL :SubGetVersion
CALL :SubZipFile
)
CALL :SubDetectInnoSetup
IF DEFINED InnoSetupPath (
TITLE Compiling installer...
"%InnoSetupPath%" /O"." /Q "installer\Subtitle_Edit_installer.iss"
IF %ERRORLEVEL% NEQ 0 GOTO EndWithError
ECHO. & ECHO Installer compiled successfully!
) ELSE (
ECHO Inno Setup wasn't found; the installer wasn't built
)
:END
TITLE Compiling Subtitle Edit finished!
ECHO.
ENDLOCAL
PAUSE
EXIT /B
:SubZipFile
TITLE Creating the ZIP file...
ECHO. & ECHO Creating the ZIP file...
PUSHD "src\bin\Release"
IF EXIST "temp_zip" RD /S /Q "temp_zip"
IF NOT EXIST "temp_zip" MD "temp_zip"
IF NOT EXIST "temp_zip\Languages" MD "temp_zip\Languages"
IF NOT EXIST "temp_zip\Dictionaries" MD "temp_zip\Dictionaries"
IF NOT EXIST "temp_zip\Ocr" MD "temp_zip\Ocr"
COPY /Y /V "..\..\..\LICENSE.txt" "temp_zip\"
COPY /Y /V "..\..\..\Changelog.txt" "temp_zip\"
COPY /Y /V "Hunspellx86.dll" "temp_zip\"
COPY /Y /V "Hunspellx64.dll" "temp_zip\"
COPY /Y /V "SubtitleEdit.exe" "temp_zip\"
COPY /Y /V "Languages\*.xml" "temp_zip\Languages\"
COPY /Y /V "..\..\..\Dictionaries\*.*" "temp_zip\Dictionaries\"
COPY /Y /V "..\..\..\Ocr\*.*" "temp_zip\Ocr\"
PUSHD "temp_zip"
START "" /B /WAIT "%SEVENZIP%" a -tzip -mx=9 "SE%VERSION%.zip" * >NUL
IF %ERRORLEVEL% NEQ 0 GOTO EndWithError
ECHO. & ECHO ZIP file created successfully!
MOVE /Y "SE%VERSION%.zip" "..\..\..\.." >NUL
POPD
IF EXIST "temp_zip" RD /S /Q "temp_zip"
POPD
EXIT /B
:EndWithError
Title Compiling Subtitle Edit [ERROR]
ECHO. & ECHO.
ECHO **ERROR: Build failed and aborted!**
PAUSE
ENDLOCAL
EXIT
:SHOWHELP
TITLE %~nx0 %1
ECHO. & ECHO.
ECHO Usage: %~nx0 [Clean^|Build^|Rebuild]
ECHO.
ECHO Notes: You can also prefix the commands with "-", "--" or "/".
ECHO The arguments are not case sensitive.
ECHO. & ECHO.
ECHO Executing %~nx0 without any arguments is equivalent to "%~nx0 build"
ECHO.
ENDLOCAL
EXIT /B
:SubGetVersion
FOR /F delims^=^"^ tokens^=2 %%A IN ('FINDSTR /R /C:"AssemblyVersion" "src\Properties\AssemblyInfo.cs.template"') DO (
rem 3.4.1.[REVNO]
SET "VERSION=%%A"
)
rem 3.4.1: 0 from the left and -8 chars from the right
SET "VERSION=%VERSION:~0,-8%"
EXIT /B
:SubDetectSevenzipPath
FOR %%G IN (7z.exe) DO (SET "SEVENZIP_PATH=%%~$PATH:G")
IF EXIST "%SEVENZIP_PATH%" (SET "SEVENZIP=%SEVENZIP_PATH%" & EXIT /B)
FOR %%G IN (7za.exe) DO (SET "SEVENZIP_PATH=%%~$PATH:G")
IF EXIST "%SEVENZIP_PATH%" (SET "SEVENZIP=%SEVENZIP_PATH%" & EXIT /B)
FOR /F "tokens=2*" %%A IN (
'REG QUERY "HKLM\SOFTWARE\7-Zip" /v "Path" 2^>NUL ^| FIND "REG_SZ" ^|^|
REG QUERY "HKLM\SOFTWARE\Wow6432Node\7-Zip" /v "Path" 2^>NUL ^| FIND "REG_SZ"') DO SET "SEVENZIP=%%B\7z.exe"
EXIT /B
:SubDetectInnoSetup
FOR /F "tokens=5*" %%A IN (
'REG QUERY "HKLM\SOFTWARE\Microsoft\Windows\CurrentVersion\Uninstall\Inno Setup 5_is1" /v "Inno Setup: App Path" 2^>NUL ^| FIND "REG_SZ" ^|^|
REG QUERY "HKLM\SOFTWARE\Wow6432Node\Microsoft\Windows\CurrentVersion\Uninstall\Inno Setup 5_is1" /v "Inno Setup: App Path" 2^>NUL ^| FIND "REG_SZ"') DO SET "InnoSetupPath=%%B\ISCC.exe"
EXIT /B