SubtitleEdit/build.bat
2014-03-24 08:39:15 +02:00

159 lines
5.0 KiB
Batchfile

@ECHO OFF
SETLOCAL
SET "VERSION=3.3.14"
SET "SEVENZIP_PATH=%PROGRAMFILES%\7-Zip\7z.exe"
CD /D %~dp0
rem Check for the help switches
IF /I "%~1" == "help" GOTO SHOWHELP
IF /I "%~1" == "/help" GOTO SHOWHELP
IF /I "%~1" == "-help" GOTO SHOWHELP
IF /I "%~1" == "--help" GOTO SHOWHELP
IF /I "%~1" == "/?" GOTO SHOWHELP
IF NOT DEFINED VS120COMNTOOLS (
ECHO Visual Studio 2013 wasn't found
GOTO EndWithError
)
IF "%~1" == "" (
SET "BUILDTYPE=Build"
) ELSE (
IF /I "%~1" == "Build" SET "BUILDTYPE=Build" & GOTO START
IF /I "%~1" == "/Build" SET "BUILDTYPE=Build" & GOTO START
IF /I "%~1" == "-Build" SET "BUILDTYPE=Build" & GOTO START
IF /I "%~1" == "--Build" SET "BUILDTYPE=Build" & GOTO START
IF /I "%~1" == "Clean" SET "BUILDTYPE=Clean" & GOTO START
IF /I "%~1" == "/Clean" SET "BUILDTYPE=Clean" & GOTO START
IF /I "%~1" == "-Clean" SET "BUILDTYPE=Clean" & GOTO START
IF /I "%~1" == "--Clean" SET "BUILDTYPE=Clean" & GOTO START
IF /I "%~1" == "Rebuild" SET "BUILDTYPE=Rebuild" & GOTO START
IF /I "%~1" == "/Rebuild" SET "BUILDTYPE=Rebuild" & GOTO START
IF /I "%~1" == "-Rebuild" SET "BUILDTYPE=Rebuild" & GOTO START
IF /I "%~1" == "--Rebuild" SET "BUILDTYPE=Rebuild" & GOTO START
ECHO. & ECHO Unsupported commandline switch!
GOTO EndWithError
)
:START
PUSHD "src"
CALL "%VS120COMNTOOLS%vsvars32.bat" x86
TITLE %BUILDTYPE%ing SubtitleEdit - Release^|Any CPU...
"MSBuild.exe" SubtitleEdit.sln /t:%BUILDTYPE% /p:Configuration=Release /p:Platform="Any CPU"^
/maxcpucount /consoleloggerparameters:DisableMPLogging;Summary;Verbosity=minimal
IF %ERRORLEVEL% NEQ 0 GOTO EndWithError
ECHO.
POPD
IF /I "%BUILDTYPE%" == "Clean" GOTO END
IF DEFINED SEVENZIP_PATH IF EXIST "%SEVENZIP_PATH%" CALL :SubZipFile
CALL :SubDetectInnoSetup
IF DEFINED InnoSetupPath (
PUSHD "installer"
TITLE Compiling installer...
"%InnoSetupPath%\iscc.exe" /O.. /Q "Subtitle_Edit_installer.iss"
IF %ERRORLEVEL% NEQ 0 GOTO EndWithError
ECHO. & ECHO Installer compiled successfully!
POPD
) ELSE (
ECHO Inno Setup wasn't found; the installer wasn't built
)
:END
TITLE Compiling Subtitle Edit finished!
ECHO.
ENDLOCAL
PAUSE
EXIT /B
:SubZipFile
TITLE Creating the ZIP file...
PUSHD "src\bin\Release"
IF EXIST "temp_zip" RD /S /Q "temp_zip"
IF NOT EXIST "temp_zip" MD "temp_zip"
IF NOT EXIST "temp_zip\Languages" MD "temp_zip\Languages"
IF NOT EXIST "temp_zip\Tesseract" MD "temp_zip\Tesseract"
IF NOT EXIST "temp_zip\Tesseract\tessdata" MD "temp_zip\Tesseract\tessdata"
IF NOT EXIST "temp_zip\Tesseract\tessdata\configs" MD "temp_zip\Tesseract\tessdata\configs"
COPY /Y /V "..\..\..\gpl.txt" "temp_zip\"
COPY /Y /V "..\..\Changelog.txt" "temp_zip\"
COPY /Y /V "Interop.QuartzTypeLib.dll" "temp_zip\"
COPY /Y /V "Hunspellx86.dll" "temp_zip\"
COPY /Y /V "NHunspell.dll" "temp_zip\"
COPY /Y /V "SubtitleEdit.exe" "temp_zip\"
COPY /Y /V "Languages\*.xml" "temp_zip\Languages\"
COPY /Y /V "..\..\..\Tesseract\msvcp90.dll" "temp_zip\Tesseract\"
COPY /Y /V "..\..\..\Tesseract\msvcr90.dll" "temp_zip\Tesseract\"
COPY /Y /V "..\..\..\Tesseract\tesseract.exe" "temp_zip\Tesseract\"
COPY /Y /V "..\..\..\Tesseract\tessdata\configs\hocr" "temp_zip\Tesseract\tessdata\configs\"
COPY /Y /V "..\..\..\Tesseract\tessdata\eng.traineddata" "temp_zip\Tesseract\tessdata\"
PUSHD "temp_zip"
START "" /B /WAIT "%SEVENZIP_PATH%" a -tzip -mx=9 "SE%VERSION%.zip" * >NUL
IF %ERRORLEVEL% NEQ 0 GOTO EndWithError
MOVE /Y "SE%VERSION%.zip" "..\..\..\.." >NUL
POPD
IF EXIST "temp_zip" RD /S /Q "temp_zip"
POPD
EXIT /B
:EndWithError
Title Compiling Subtitle Edit [ERROR]
ECHO. & ECHO.
ECHO **ERROR: Build failed and aborted!**
PAUSE
ENDLOCAL
EXIT
:SHOWHELP
TITLE %~nx0 %1
ECHO. & ECHO.
ECHO Usage: %~nx0 [Clean^|Build^|Rebuild]
ECHO.
ECHO Notes: You can also prefix the commands with "-", "--" or "/".
ECHO The arguments are not case sensitive.
ECHO. & ECHO.
ECHO Executing %~nx0 without any arguments is equivalent to "%~nx0 build"
ECHO.
ENDLOCAL
EXIT /B
:SubDetectInnoSetup
rem Detect if we are running on 64bit Windows and use Wow6432Node since Inno Setup is
rem a 32-bit application, and set the registry key of Inno Setup accordingly
IF DEFINED PROGRAMFILES(x86) (
SET "U_=HKLM\SOFTWARE\Wow6432Node\Microsoft\Windows\CurrentVersion\Uninstall"
) ELSE (
SET "U_=HKLM\SOFTWARE\Microsoft\Windows\CurrentVersion\Uninstall"
)
FOR /F "delims=" %%a IN (
'REG QUERY "%U_%\Inno Setup 5_is1" /v "Inno Setup: App Path"2^>Nul^|FIND "REG_"') DO (
SET "InnoSetupPath=%%a" & CALL :SubInnoSetup %%InnoSetupPath:*Z=%%)
EXIT /B
:SubInnoSetup
SET "InnoSetupPath=%*"
EXIT /B