Being lazy with printing the banner seems hard to reason with, we should print it
unconditionally first (it could also lead to duplicate banners if we
have multiple functions in -filter-print-funcs).
The printIR() functions were doing too many things. I separated out the
call from PrintPassInstrumentation since we were essentially doing two
completely separate things in printIR() from different callers.
There were multiple ways to generate the name of some IR. That's all
been moved to getIRName(). The printing of the IR name was also
inconsistent, now it's always "IR Dump on $foo" where "$foo" is the
name. For a function, it's the function name. For a loop, it's what's
printed by Loop::print(), which is more detailed. For an SCC, it's the
list of functions in parentheses. For a module it's "[module]", to
differentiate between a possible SCC with a function called "module".
To preserve D74814, we have to check if we're going to print anything at
all first. This is unfortunate, but I would consider this a special
case that shouldn't be handled in the core logic.
Reviewed By: jamieschmeiser
Differential Revision: https://reviews.llvm.org/D100231
This instruments a should-run-optional-pass callback using the existing
OptBisect class to decide if new passes should be skipped. Passes that
force isRequired never reach this at all, so they are not included in
"BISECT:" output nor its pass count.
The test case is resurrected from r267022, an early version of D19172
that had new pass manager support (later reverted and redone without).
Reviewed By: aeubanks
Differential Revision: https://reviews.llvm.org/D87951
This patch implements a optimization bisect feature, which will allow optimizations to be selectively disabled at compile time in order to track down test failures that are caused by incorrect optimizations.
The bisection is enabled using a new command line option (-opt-bisect-limit). Individual passes that may be skipped call the OptBisect object (via an LLVMContext) to see if they should be skipped based on the bisect limit. A finer level of control (disabling individual transformations) can be managed through an addition OptBisect method, but this is not yet used.
The skip checking in this implementation is based on (and replaces) the skipOptnoneFunction check. Where that check was being called, a new call has been inserted in its place which checks the bisect limit and the optnone attribute. A new function call has been added for module and SCC passes that behaves in a similar way.
Differential Revision: http://reviews.llvm.org/D19172
llvm-svn: 267022